Hall Effect Current Transducer with closed Loop 25A, for the electronic measurement of currents up 25A: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high power) and the secondary (electronic) circuits.
Basic information:
Marking manufacturer | NACL.25T4-P6/VN |
Type of component: | Hall Closed Loop |
Configuration: | Input THT |
Specification: | Input AC/DC |
Case type: | THT |
Tolerance of nominal value | ± 0.70 % |
RoHS | Yes |
REACH | No |
UL94 | Plastic case UL-V0 |
Packaging and weight:
Unit: | pcs |
Weight: | 13.2 [g] |
Type of packaging: | BOX |
Small package (Number of units): | 25 |
Electro-physical parameters:
Idc-in nom | 25 [A] |
Idc-in max | 80 [A] |
IAC-IN nominal (TC/TA=25°C) | 25 [A] |
Udc-sup.min (Min.Supply DC Voltage) | 4.75 [V] |
Udc-sup.nom (Nom.Supply DC Voltage) | 5 Vdc [V] |
Udc-sup.max (Max.Supply DC Voltage) | 5.25 [V] |
Uisol (@25°C/1min/50Hz) | 2500 [V] |
f max | 200 [kHz] |
Transformation ratio: | 1: 1200 |
Thermal and mechanical parameters:
Tmin (minimum working temperature) | -40 [°C] |
Tmax (maximum working temperature) | 105 [°C] |
Number of Pins | 9 |
D1 - Inner diameter | 5 [mm] |
L - Length | 22.2 [mm] |
W - Width | 13 [mm] |
H - Height | 22.7 [mm] |
Alternatives and replacements
Alternative 1: | 178608 - Ltrp LTS 25-NP (LEM) |
Alternative products 1: | LTS 25-NP |