Hall Effect Current Transducer 200A AC, DC
Basic information:
Marking manufacturer | HAIS200-P |
Type of component: | Hall Open Loop |
Configuration: | Input Hole |
Specification: | Input AC/DC |
Case type: | THT |
Tolerance of nominal value | ± 1 % |
RoHS | Yes |
REACH | No |
NOVINKA | N |
UL94 | Plastic case UL-V0 |
Packaging and weight:
Unit: | pcs |
Weight: | 20.174 [g] |
Type of packaging: | BOX |
Small package (Number of units): | 25 |
Electro-physical parameters:
Idc-in nom | 200 [A] |
Idc-in max | 600 [A] |
IAC-IN nominal (TC/TA=25°C) | 100 [A] |
Udc-sup.min (Min.Supply DC Voltage) | 4.75 [V] |
Udc-sup.nom (Nom.Supply DC Voltage) | 5 Vdc [V] |
Udc-sup.max (Max.Supply DC Voltage) | 5.25 [V] |
Uisol (@25°C/1min/50Hz) | 2500 [V] |
f max | 50 [kHz] |
Thermal and mechanical parameters:
Tmin (minimum working temperature) | -40 [°C] |
Tmax (maximum working temperature) | 85 [°C] |
Number of Pins | 4 |
D1 - Inner diameter | 8 [mm] |
L - Length | 33 [mm] |
W - Width | 14 [mm] |
H - Height | 29 [mm] |